CAT-0016 / CELL RECORD
45 Ah · 3.2 V pouch cell
A documented cell supply option for procurement discussions. We coordinate requirements, documentation and samples; technical suitability is confirmed by the manufacturer or customer.
45 AhCapacity
3.2 VNominal voltage
763 ±20 gCell mass
Specification revision: trial · 2025-10-29

The illustration shows a generic cell form, not the exact catalogue item.
SPECIFICATIONS & CONDITIONS
Keep the conditions
with the number.
| Field | Specification and context |
|---|---|
| Nominal capacity | 45 Ah0.33C capacity referenceSpecification PDF page 5 |
| Nominal voltage | 3.2 VSpecification PDF page 5 |
| Charge cutoff voltage | 3.65 VSpecification PDF page 5 |
| Discharge cutoff voltage | 2 VSpecification PDF page 5 |
| Dimensions · T × W × L | 11.2 ±0.3 × 146 ±2 × 206 ±2 mmThickness × width × length; tab dimensions are specified separately.Specification PDF page 3 |
| Cell mass | 763 ±20 gSpecification PDF page 6 |
| Standard charge reference | 0.33CStandard charge reference; confirm temperature and cutoff conditions.Specification PDF page 5 |
| Fast charge reference | To be confirmedFast charge method in the specification; not a universal charge rating.Specification PDF page 5 · To confirm |
| Rate discharge reference | 3CRate discharge method in the specification; temperature and system integration require review.Specification PDF page 5 |
| Short-duration discharge | To be confirmedNo separate duration-rated figure provided.Specification PDF page 5 · To confirm |
| Cycle-life reference | To be confirmedDocument endpoints differ; confirm the agreed revision.Specification PDF page 5 · To confirm |
| Cell energy density | ≥190 Wh/kgCell-level weight energy density; standard method in sections 5.1–5.2.Specification PDF page 6 |
| Charge operating temperature | 0–60 °CSpecification PDF page 5 |
| Discharge operating temperature | -20–60 °CSpecification PDF page 5 |
| Maximum charge reference | 3CNot applicable to cycle testing.Specification PDF page 5 |
Make the next discussion specific.
Prepare your procurement object, application, quantity and key requirements. Unknown technical items can be confirmed during follow-up.