C-rate, current and pulse duration

Convert C to A, then check the allowed duration, voltage and thermal conditions.

Content updated 2026-10-13 · Technical guide for procurement discussions

C-rate expresses current relative to capacity. A short-duration rating needs its duration and conditions; it cannot establish a continuous rating.

Normal dutyPeakRecoverySequence / time →
Original conceptual load sequence. Relative levels only; not a product discharge curve or a recommended duty.

Converting a C-rate into current

For a 20 Ah example, 1C corresponds to 20 A and 3C corresponds to 60 A. The one-hour scale used in the definition does not guarantee an actual one-hour operating time: voltage cutoff, load and temperature still matter.

Relationship / example
I (A) = C-rate × Q (Ah)
3 × 20 Ah = 60 A

Reference: Texas Instruments · Drone / robot battery-management reference

Continuous operation and a time-limited peak

Describe a demand as a load sequence: normal operation, start-up or acceleration, peak duration, and recovery. Two loads with the same peak current can impose different requirements when their durations or repetition differ.

ReferenceInformation to retain
Continuous currentPermitted duty, temperature, voltage limits and heat-removal conditions.
Short-duration currentDuration, initial SOC, temperature, cutoff voltage and recovery or repetition.
Charging rateCharge method, SOC interval, voltage cutoff and termination.

Reference: INL / US DOE · Battery Test Manual for Electric Vehicles

Power requires the operating voltage

Electrical power is voltage multiplied by current. A nominal-voltage calculation helps express an initial target, but the voltage under load is needed for an operating-power assessment. Peak power, usable energy and thermal behaviour are separate inputs to the evaluation.

Relationship / example
P (W) = V_load (V) × I (A)
Nominal example: 22.2 V × 60 A = 1,332 W

Questions to prepare

  • What are the continuous and peak current or power targets?
  • How long does each peak last, and how often does it repeat?
  • What minimum loaded voltage and temperature limits must the system respect?
Send your procurement enquiry

Common questions

Is the largest stated C-rate always continuous?

Check the definition. A maximum may refer to a limited pulse, SOC interval or test condition.

Does doubling parallel count double permitted pack current?

Ideal current arithmetic is only a reference. Connections, current sharing, protection and thermal limits require pack-level confirmation.