Ah measures charge capacity; Wh measures energy; Wh/kg and Wh/L express that energy per unit mass or volume. Use these quantities together to compare battery candidates. Evaluate runtime and power with the operating load, usable-energy window and complete-pack configuration.
Set a common comparison basis: the cell or pack being assessed, load, temperature, voltage limits and included hardware. With those inputs defined, energy calculations become reproducible and useful for purchasing decisions.
Cell
Cell energy ÷ cell mass
Cells + hardware
Connections, management, enclosure
Complete pack
Pack energy ÷ complete pack mass
1. Capacity, energy and power answer different questions
An ampere-hour measures charge: 1 Ah equals 3,600 coulombs, and 1,000 mAh equals 1 Ah. A watt measures the rate of energy transfer; a watt-hour measures energy. Operating at 100 W for one hour requires 100 Wh. Compare that requirement with battery output at the relevant duty.
A rechargeable cell stores and releases energy through electrochemical processes. Its terminal voltage changes with state and operating conditions, so energy depends on both delivered charge and the voltage at which it is delivered. S01
Scroll horizontally to read every column.
| Quantity | Common unit | What it helps answer | What it does not establish |
|---|---|---|---|
| Charge capacity | Ah, mAh | How much charge is delivered in the specified test? | Energy without a voltage basis |
| Energy | Wh, kWh | How much electrical energy is delivered or rated? | How quickly it may safely be delivered |
| Power | W, kW | How quickly is energy being delivered? | How long that output can continue |
| Specific energy | Wh/kg | How much energy per unit mass? | Pack performance if only a cell was measured |
| Volumetric energy density | Wh/L | How much energy per unit volume? | Installation fit without a defined envelope |
| Specific power | W/kg | How much power per unit mass under stated conditions? | Stored energy or runtime |
In commercial conversation, “energy density” often means Wh/kg. Technically, it is helpful to distinguish mass-specific energy from volumetric energy density. Always include the unit rather than assuming everyone means the same thing.
2. Converting Ah to nominal Wh
The usual nominal-energy calculation is:
E_nominal (Wh) = V_nominal (V) × Q_nominal (Ah)
Hypothetical comparison: a 20 Ah cell at 3.65 V has 73 Wh of nominal energy; a 20 Ah cell at 3.20 V has 64 Wh. Equal Ah therefore accompanies different nominal energy when voltage differs.
Use nominal voltage and nominal capacity for this first-pass energy comparison. The discharge curve provides the changing voltage during operation. Keep charge-cutoff voltage in its separate role as an operating limit.
When a supplier’s energy figure differs from the calculation, identify its capacity and voltage basis. Minimum capacity, typical capacity and integrated discharge energy describe different quantities. Document the basis of each result and resolve the difference before ranking candidates.
3. Measured energy follows the discharge curve
The electrical energy delivered at the battery terminals is the integral of voltage multiplied by current over time:
E_discharge (Wh) = ∫ V(t) × I(t) dt, with time expressed in hours.
A test system calculates discharge energy from sampled voltage and current. Record the discharge conditions and endpoint so that the measured energy can be compared with other tests. S02
Hypothetical measurement record: each voltage below is the average for its segment, with the stated constant current and duration.
Scroll horizontally to read every column.
| Segment | Current | Duration | Average voltage | Charge delivered | Energy delivered |
|---|---|---|---|---|---|
| First | 10 A | 0.5 h | 3.9 V | 5 Ah | 19.5 Wh |
| Second | 10 A | 0.5 h | 3.6 V | 5 Ah | 18.0 Wh |
| Third | 10 A | 0.5 h | 3.3 V | 5 Ah | 16.5 Wh |
| Total | — | 1.5 h | — | 15 Ah | 54.0 Wh |
Summing the segments gives 54 Wh. Dividing by 15 Ah yields a charge-weighted average discharge voltage of 3.6 V. For a test with varying current, calculate the voltage-current product at each interval and integrate it; multiplying separate averages can lose their time-dependent relationship.
Record the endpoint and test conditions with measured energy. Different cutoff voltages, temperatures and loads define different measurements and answer different application questions.
4. Calculate cell and pack specific energy at their own mass boundaries
For a defined object:
Specific energy (Wh/kg) = Energy (Wh) / Mass (kg)
A complete pack includes more than its active cells: connections, insulation, monitoring and protection, mechanical support, an enclosure and sometimes thermal-management hardware. System-level battery models treat those components as part of the pack's mass and cost. S08
Hypothetical example: assume a 3.7 V, 20 Ah cell with a mass of 0.25 kg. Its nominal energy is 74 Wh and its nominal specific energy is 296 Wh/kg. Six identical cells contain 444 Wh and weigh 1.5 kg.
Add an assumed 0.4 kg of pack hardware:
Complete-pack mass = 1.5 + 0.4 = 1.9 kg
Nominal pack specific energy = 444 / 1.9 ≈ 233.7 Wh/kg
The added hardware increases the denominator from cells-only mass to complete-pack mass. The nominal energy remains the same in this example, so the reduced Wh/kg follows directly from the wider mass boundary.
Evaluate accessible energy separately: the operating window and electrical losses determine how much of the 444 Wh reaches the application. Added mass changes Wh/kg; limited access to energy changes delivered Wh.
5. Wh/L depends on what volume you count
The corresponding volume calculation is:
Volumetric energy density (Wh/L) = Energy (Wh) / Volume (L)
For a rectangular envelope, one litre equals 1,000,000 mm³. An assumed 20 × 100 × 150 mm body occupies 0.30 L. If its nominal energy is 73 Wh, the resulting body-based value is about 243.3 Wh/L.
For installation, add tab and terminal clearance, swelling allowance, insulation, support and cooling passages to the cell-body envelope. Cylindrical body volume and the rectangular space allocated in a pack are also distinct measurements.
Compare the same boundary on each side: cell body, installation envelope or complete pack. Use the actual assembly drawing to confirm fit inside the required enclosure.
6. Separate nominal energy, accessible battery energy and energy at the load
There are several legitimate energy boundaries:
Nominal energy comes from the stated voltage-capacity calculation. Energy delivered by the battery is measured across a defined operating window and duty. Energy reaching the equipment additionally depends on the path between battery terminals and the load.
For preliminary planning, a simplified expression can be useful:
E_load ≈ E_reference × usable-energy fraction × conversion efficiency
Hypothetical scenario: start with the 444 Wh nominal pack example, assume an accessible energy fraction of 80%, and assume 92% conversion efficiency. The result is approximately 326.8 Wh at the load. At an assumed constant 200 W load, that corresponds to about 1.63 hours.
Under these assumptions, the runtime estimate is 1.63 hours. The 80% input represents accessible energy, while SOC describes a state-of-charge basis; their relationship depends on the voltage curve and duty. Chemistry-aware fuel-gauge methods account for these relationships through a cell model and measurements. S10
Account for each effect once. Where a measured usable-energy result already includes the voltage window and temperature, retain that measurement basis without an additional adjustment for the same factors. Add aging or other environmental effects only where they remain outside the evidence.
7. Match the energy target to the required power
Energy and power require separate checks. During a demanding duty, voltage, temperature or current limits can determine the output available from a cell that still holds charge. Reference testing therefore characterizes both energy delivery and power capability. S02
Request energy available at the required load. Include the lowest accepted system voltage, peak duration, repetition and temperature; these conditions define the usable portion of the discharge curve.
Rank candidates by their ability to meet the energy requirement at the specified power, temperature, size, life and cost.
8. Keep typical, minimum and measured values separate
A specification of ≥ 270 Wh/kg, a typical value of 270 Wh/kg, and a particular sample measuring 270 Wh/kg are different statements. Preserve the qualifier and test basis.
State whether mass is maximum, typical or measured, and use a matching energy basis. Capacity and mass tolerances can support an arithmetic plausibility interval. Label it as such; statistical confidence or guaranteed measured performance requires the corresponding evidence.
When an update differs from an earlier specification, establish the actual product and revision, the energy measurement or calculation, and the mass boundary. These checks explain whether the difference is a product change or a reporting change.
9. Compare price per nominal energy on a common commercial basis
For a stated commercial and technical basis:
Cost per nominal Wh = Unit price / Nominal energy
Two hypothetical quotations—$18 for 72 Wh and $20 for 80 Wh—both give $0.25 per nominal Wh. Normalizing by energy reveals their equal nominal-energy cost despite different unit prices.
Then align quantity, delivery terms, included documents, product state and integration scope. Cell-only and finished-pack quotations require separate accounting for the additional hardware and work.
Use price per nominal Wh for an initial screen. A lifetime-cost comparison adds delivered energy over the duty and aging history, calendar exposure, operating costs, replacement work and residual value. Lifetime output requires those inputs rather than a multiplication of cycle count by nameplate Wh.
10. A comparison record buyers can actually use
Scroll horizontally to read every column.
| Record | Information to retain |
|---|---|
| Product identity | Manufacturer/model, proposed revision and whether the object is a cell or pack |
| Capacity and energy | Typical or minimum basis; nominal calculation or measured Wh |
| Test method | Charge preparation, discharge current/power, temperature and cutoff |
| Mass and volume | Included hardware, tolerances, measurement state and installation envelope |
| Application boundary | Battery terminals or load input; conversion and auxiliary consumption |
| Operating life | New-product condition or defined end-of-service requirement |
| Commercial basis | Quantity, unit price, delivery term and included scope |
This record is useful across brands. It lets a buyer see whether two apparently different energy-density figures describe a genuine performance difference or merely different reporting boundaries.
Common questions
Does more Ah always mean longer runtime?
Runtime depends on energy at the required voltage and load, the usable-energy window and conversion losses. Compare those quantities before using Ah to rank candidates.
Does connecting cells in series increase Ah?
For identical cells in ideal arithmetic, series count increases voltage and parallel count increases Ah. Both increase total nominal energy through the total cell count. Confirm actual operation at pack level.
Can I replace a datasheet's Wh/kg with my own calculation?
Keep the calculated value in a separate field with its assumptions. Establish equivalence of voltage, capacity, mass and test basis before reconciling it with the specified value.
Is a lower USD/Wh number automatically the better buy?
Use USD/Wh to compare equivalent products, quantities and included scope. Evaluate usable energy, life cost and application suitability separately.
Continue from the calculation to a procurement shortlist
Use the battery pack calculator for nominal arithmetic, then read the C-rate and load guide and application selection guide. Bring both the numerical target and its operating conditions to the sourcing discussion.
CELL & PACK sources featured catalogue cells and other Chinese battery brands and models. Send your requirements with the energy target, product level, mass or volume limits, load and destination. We coordinate product information and procurement; manufacturer or customer engineering teams establish application design and technical acceptance.
Sources and further reading
- S01 U.S. Department of Energy. DOE Explains…Batteries.
- S02 Idaho National Laboratory / U.S. DOE. Battery Test Manual for Electric Vehicles, Revision 3 (June 2015), INL/EXT-15-34184.
- S08 Argonne National Laboratory. Modeling the Performance and Cost of Lithium-Ion Batteries for Electric-Drive Vehicles, Third Edition.
- S10 Texas Instruments. BQ34Z100-G1 multi-chemistry fuel gauge.