CATALOGUE-BASED CONVERSION

Battery Pack Calculator
Based on Our Pouch Cells

Choose a catalogue cell, then enter your reference series and parallel counts. Voltage, capacity and mass come from that cell’s published specification revision.

Choose a catalogue cell
Enter reference counts

Positive whole numbers

Positive whole numbers

Counts express your reference scenario. Confirm the actual pack configuration with the manufacturer or your technical team.

Add scenario assumptions (optional)

Enter values you want to discuss. These fields start blank and do not establish product ratings or measured usable energy.

Positive value, with duty and duration to confirm.

Enclosure, BMS, connections and other included hardware.

0–100% arithmetic share; not a verified SOC or DOD window.

Selected cell’s discharge reference

Select a cell to view its published reference.

Enable JavaScript and select a cell to use the conversion tool.

Use the results in procurement discussions

The tool uses one selected cell specification and identical-cell arithmetic. Technical suitability, permitted current, matching, thermal design and runtime are confirmed by the manufacturer or customer.

If you choose to include parameters, the enquiry link carries the cell reference, counts and valid optional numbers. Contact details and project text are not included in that link. You can edit or remove the scenario before submitting.

WORKED EXAMPLE

What does 6S1P mean for CAT-0012?

Arithmetic example, not a configuration recommendation.

CAT-0012 : 20 Ah / 3.65 V. Assume six identical cells in series and one parallel string (6S1P).

Nominal voltage
6 × 3.65 V = 21.9 V
Nominal capacity
1 × 20 Ah = 20 Ah
Nominal energy
21.9 V × 20 Ah = 438 Wh
Cells-only mass reference
6 × 243 g = 1.458 kg

Datasheet revision: V2.0 · 2026-02-03. Mass uses the central specification value and excludes BMS, enclosure and connections. This nominal arithmetic does not establish usable energy, permitted current, runtime or design suitability.

The relationships used here

V_pack = N_s × V_cell
Q_pack = N_p × Q_cell
E_nom = V_pack × Q_pack
m_cells = N_s × N_p × m_cell
m_pack = m_cells + m_hardware
I_reference = C_assumed × Q_pack
P_reference = V_pack × I_reference

m_hardware is the additional pack mass you enter; C_assumed is the C-rate assumption you enter.

Reference: Texas Instruments · Drone / robot battery-management reference · Argonne National Laboratory · BatPaC v5.0 manual

Compare cell specifications

Compare the attached conditions as well as the numbers. Technical suitability and current supply terms are confirmed for the project.